How to Maintain Capsule Filling Machine?

As a China Pharmaceutical Equipment Factory, I would like to share with you. Capsule filling machine maintenance:

Automatic Capsule Filling Machine

Automatic Capsule Filling Machine

Clean up parts

1. When the machine normally works for a long time, it is necessary to regularly clean up the direct contact with the medicine. When the batch of medicine is changed or the time is out of use for a long time, it must be cleaned.

Add lubricating oil

2. The transmission mechanism under the working table of the machine should be frequently added with lubricating oil (grease) in an appropriate amount to reduce the wear of moving parts.

Check the oil level

3. The oil quantity of the main drive reducer should be checked once a month. If it is insufficient, the oil should be refilled in time, and the lubricant should be replaced every six months; the indexing box of the turntable should be replaced every 3000 hours of operation. According to experience, 90 is generally used.

Safety clutch

4. The safety clutch acts as a protection when the machine is overloaded. The clutch should not slip when the load is normal, but it may also slip due to long-term use. When slipping occurs in normal use, the round nut of the clutch can be tightened. Some, in order to achieve the purpose of ensuring the normal operation of the machine and protecting it.

Vacuum separator

5. The vacuum separator of the vacuum system mainly plays the role of sucking the capsule into the upper and lower modules and separating the cap and the body during the filling of the hard capsule. If the capsule cannot separate the cap and the body, the subsequent filling will not be possible. Every time the turntable of the machine rotates one station, the main shaft of the machine rotates one round, and the vacuum separator moves up and down once under the action of the cam. If the cap and body of the capsule are not separated smoothly, check the gap between the upper plane of the vacuum separator and the lower plane of the lower module. If the gap is too large, the vacuum degree of the vacuum system will not reach the vacuum degree required by the cap and body separation ( About 0.05MPa), the gap is too small and it is easy to cause head collision to deform the lower module. When the position of the vacuum separator needs to be adjusted, use the handle to rotate the main motor shaft to raise the vacuum separator to the highest position, and loosen the lock nuts at both ends of the adjusting rod under the machine table (one is left-handed nut, one is right-handed nut ), then rotate the adjusting rod to adjust the height of the vacuum separator, then tighten the nut, and use the handle to rotate the main motor shaft to test until it is suitable. The vacuum degree is read on the vacuum gauge on the operation panel of the machine. When the vacuum is too high, the vacuum degree regulating valve can be opened appropriately, and when the vacuum is too low, the vacuum degree regulating valve can be closed or closed. The filter of the vacuum system should be opened regularly to remove the clogged dirt to ensure that the vacuum system has sufficient vacuum.

Our company also has Automatic Capsule Filling Machine on sale, welcome to contact us.